CF 146 11 V- Rev. 1.0 - 003R-620-100
TARG.HI Target for Overweight
Setpoint 1 (Output 1)
-99999 to 999999
Default = 000000
Accept
TARG.LO Target for Underweight
Setpoint 2 (Output 2)
-99999 to 999999
Default = 000000
Accept
FORMAT Date Format Setting dd.mm.yy or mm.dd.yy Accept
YEAR Year Setting 2000 to 2099
<SEL> changes position, <EDT> changes digit.
Accept
MONTH Month Setting 01 to 12
<SEL> changes position, <EDT> changes digit.
Accept
DAY Day Setting 01 to 31
<SEL> changes position, <EDT> changes digit.
Accept
HOUR Hour Setting 00 to 23
<SEL> changes position, <EDT> changes digit.
Accept
CLOC
MINUTE Minute Setting 00 to 59
<SEL> changes position, <EDT> changes digit.
Accept
SCALE Scale Base Test Display Display reads in milliVolts-per-Volt (factory calibrated to 0.1%)
Verify the correct load cell capacity and/or load cell wiring is used. Remove weight
from scale.
TEST
FRC.OUT Force Outputs <EDT> advances through outputs (i.e. ON.1 and ON.2)
<OK> turns outputs off and exits test.
Default = OFF
FACTRY DEFLT Restore Factory Defaults
Cont. N (No)
Cont. Y (Yes)
Cont. N
Warning: Choosing Cont. Y will clear all stored data except BUILD and CAL
menus.
Accept
- END - EXIT SETUP Save settings and return to
normal weighing mode
Accept