CF 195
Users Guide
Model 7i Digital Force/Torque Indicator
www.cooperinstruments.com
PH: 540-349-4746 FAX: 540-347-4755
Przeglądanie stron 0
1 2 3 4 5 6 ... 41 42

Podsumowanie treści

Strona 1 - Users Guide

CF 195 Users Guide Model 7i Digital Force/Torque Indicator www.cooperinstruments.com PH: 540-349-4746  FAX: 540-347-4755

Strona 2 - TABLE OF CONTENTS

Model 7i Digital Force / Torque Indicator User’s Guide 9MODE Toggles between measurement modes. (DOWN) Navigates down through the menu a

Strona 3 - 1 OVERVIEW

Model 7i Digital Force / Torque Indicator User’s Guide 10Current Reading – Applies to the peak capture rate of the instrument. Displayed R

Strona 4

Model 7i Digital Force / Torque Indicator User’s Guide 11 – the displayed value is greater than the upper set point (NO GO HIGH) – th

Strona 5 - 2 POWER

Model 7i Digital Force / Torque Indicator User’s Guide 12To enable Break Detection and configure the automatic functions, select Break Dete

Strona 6 - 3 SETUP

Model 7i Digital Force / Torque Indicator User’s Guide 13 7.3 Auto Output Settings Scroll to Auto Settings in the Break Detection menu and

Strona 7

Model 7i Digital Force / Torque Indicator User’s Guide 148.1 Real Time (RT) The primary reading corresponds to the live measured reading.

Strona 8 - 4 HOME SCREEN AND CONTROLS

Model 7i Digital Force / Torque Indicator User’s Guide 15Parameter Description Initial Delay The time delay, in seconds, before the averagi

Strona 9

Model 7i Digital Force / Torque Indicator User’s Guide 169.5 External Trigger (ET) This mode of operation is useful for measuring electrica

Strona 10 - 5 DIGITAL FILTERS

Model 7i Digital Force / Torque Indicator User’s Guide 179.5.1 External Trigger Schematic Diagram 14GND1IN22kSWITCH UNDER TESTGAUGE+3.3VTO

Strona 11 - 6 SET POINTS

Model 7i Digital Force / Torque Indicator User’s Guide 18 Select “+ More” for additional options: 9.6.3 Stop Condition Data capture i

Strona 12 - 7 BREAK DETECTION

Model 7i Digital Force / Torque Indicator User’s Guide 1Thank you… Thank you for purchasing a Mark-10 Model 7i force/torque indicator, de

Strona 13

Model 7i Digital Force / Torque Indicator User’s Guide 19Note 2: Data capture may be manually stopped at any time by pressing the ZERO key.

Strona 14 - Caution!

Model 7i Digital Force / Torque Indicator User’s Guide 20 9.7.2 Peak Settings The display appears as follows: Thresholds and percentage

Strona 15

Model 7i Digital Force / Torque Indicator User’s Guide 219.7.3 Auto Output Settings Scroll to Auto Output Settings and press ENTER to selec

Strona 16

Model 7i Digital Force / Torque Indicator User’s Guide 22the desired reading and press DELETE. The letter “D” appears to the left of the re

Strona 17

Model 7i Digital Force / Torque Indicator User’s Guide 23 If no option is selected, this screen will be displayed indefinitely, or until b

Strona 18 - USER - SUPPLIED

Model 7i Digital Force / Torque Indicator User’s Guide 2412 COEFFICIENT OF FRICTION The 7i, with an appropriate force sensor, can dete

Strona 19

Model 7i Digital Force / Torque Indicator User’s Guide 25 14 COMMUNICATIONS AND OUTPUTS Communication with the 7i indicator is achieved

Strona 20

Model 7i Digital Force / Torque Indicator User’s Guide 26 Selection Description Numeric + Units Output format includes the value and unit

Strona 21

Model 7i Digital Force / Torque Indicator User’s Guide 27 14.3 Analog Output This output can be used for chart recorders, oscilloscopes, d

Strona 22

Model 7i Digital Force / Torque Indicator User’s Guide 2814.5 I/O Connector Pin Diagram (DB-9HD-15 female) * Maximum vo

Strona 23

Model 7i Digital Force / Torque Indicator User’s Guide 21 OVERVIEW 1.1 List of included items Qty. Part No. Description 1 12-1049 Ca

Strona 24 - 11 FOOTSWITCH

Model 7i Digital Force / Torque Indicator User’s Guide 2914.6 Command Set / Gauge Control Language 2 (GCL2) The 7i may be controlled by an

Strona 25 - 13 CUSTOM UNIT

Model 7i Digital Force / Torque Indicator User’s Guide 30 Memory & Statistics MEM Transmit all stored readings STA Transmit sta

Strona 26

Model 7i Digital Force / Torque Indicator User’s Guide 31 Other Commands AOFFn Auto-shutoff. n=0-30 minutes. 0=auto shutoff disabled

Strona 27

Model 7i Digital Force / Torque Indicator User’s Guide 32 Selecting “Cancel” will revert back to the Calibration setup. Selecting “Exit w/

Strona 28

Model 7i Digital Force / Torque Indicator User’s Guide 33 Optionally exercise the sensor several times (at full scale, if possibl

Strona 29

Model 7i Digital Force / Torque Indicator User’s Guide 34 Press ENTER. 11. At the completion of the tension calibration, the dis

Strona 30

Model 7i Digital Force / Torque Indicator User’s Guide 35Causes: 1. The calibration weight does not match the set value. 2. If using a

Strona 31

Model 7i Digital Force / Torque Indicator User’s Guide 3616.3 Locking Out Other Keys Other keys may be locked out individually. Select any

Strona 32 - 15 CALIBRATION

Model 7i Digital Force / Torque Indicator User’s Guide 37Selection Description Disabled Disable automatic shutoff. Enabled Enable automatic

Strona 33

Model 7i Digital Force / Torque Indicator User’s Guide 38 17.5 Initial settings This section is used to configure the initial settings up

Strona 34

Model 7i Digital Force / Torque Indicator User’s Guide 3Example 1 Model MR01-100 sensor with Model 7i Indicator MR01-100 ±0.15% of full sc

Strona 35

Model 7i Digital Force / Torque Indicator User’s Guide 3918 SPECIFICATIONS 18.1 General Accuracy: ±0.1% of full scale + sensorSampli

Strona 36 - 16 PASSWORDS

Model 7i Digital Force / Torque Indicator User’s Guide 40 Data Format Numeric + Units Auto Output Disabled Outputs per Sec

Strona 37 - 17 OTHER SETTINGS

WARRANTY REPAIR POLICY Limited Warranty On Products Any Cooper Instruments product which, under normal operating conditions, proves defective in ma

Strona 38

Model 7i Digital Force / Torque Indicator User’s Guide 48. Typical materials able to be tested include many manufactured items, such as sp

Strona 39

Model 7i Digital Force / Torque Indicator User’s Guide 5off), a message appears, “BATTERY VOLTAGE TOO LOW. POWERING OFF”. An audio tone wil

Strona 40 - 18 SPECIFICATIONS

Model 7i Digital Force / Torque Indicator User’s Guide 6on the printed circuit boards. 3.3 Mounting to a plate The 7i

Strona 41

Model 7i Digital Force / Torque Indicator User’s Guide 74 HOME SCREEN AND CONTROLS 4.1 Home Screen No. Name Description 1 Mea

Strona 42 - Repair Warranty

Model 7i Digital Force / Torque Indicator User’s Guide 8 N – Newton kN – Kilonewton mN – Millinewton Torque units: